Dust Sensor Unit

★Under development

Output
Features
Model No.
Analog output
Pulse analog output, single-shot detection of house dust, general purpose
Pulse analog output, single-shot detection of house dust, high sensitivity
GP2Y1012AU0F
Digital output
 
Digital (PWM) output, built-in microprocessor controller, single-shot detection of house dust, high sensitivity
GP2Y1023AU0F
Digital (UART) output, built-in microprocessor controller, sensing can discriminate between PM2.5 and PM10, internal cleaning possible
★GP2Y1030AU0F
(Ta = 25°C)
Model No.
Features
Topr
(°C)
Operating
supply voltage (V)
Electro-optical characteristics
Dissipation
current
(mA)
Detection concentration
µg/m3 (TYP.)
Output
•Built-in infrared emitting diode, photodiode and signal processing circuit
•Compact, single-shot detection of house dust
•Output: Analog voltage
–10 to +65
4.5 to 5.5
TYP. 11
0 to 600
Analog voltage
GP2Y1012AU0F
•High sensitivity
•Built-in infrared emitting diode, photodiode and signal processing circuit
•Compact, single-shot detection of house dust
•Output: Analog voltage
4.5 to 5.5
TYP. 11
0 to 240
Analog voltage
GP2Y1023AU0F
•High sensitivity
•Built-in microcomputer
•Built-in infrared emitting diode, photodiode and signal processing circuit
•Compact, single-shot detection of house dust
•Output: Digital signal output (PWM)
4.75 to 5.25
TYP. 15
0 to 240
Digital signal (PWM)
Temperature correction
Averaging
★GP2Y1030AU0F
•Built-in infrared emitting diode,
photodiode and signal processing circuit
•Built-in microcomputer
•Sensing can discriminate between PM2.5 and PM10
•Internal cleaning possible
3 to 5.5
TYP. 25
0 to 500
Digital signal (UART)

GP2Y1010AU0F
(GP2Y1012AU0F, GP2Y1023AU0F)
GP2Y1030AU0F
※Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Except where specially indicated, models listed on this page comply with the RoHS Directive*. For details, please contact SHARP.
*RoHS Directive: Prohibits use of lead, cadmium, hexavalent chromium, mercury and specific brominated flame retardants (PBBs and PBDEs), with certain exceptions.
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.